113.3-20-110

GN 113.3 Roestvrijstalen kogelvergrendelpennen

AISI 303, met holte voor grip
  • Icons/__logo__INOX__.png
  • Icons/__logo__RoHS__.png

Lt: 1-2 weken Alle maten en varianten van GN 113.3

🔒 Prijzen, actuele voorraad & CAD-downloads

Meld u aan om uw prijzen en voorraad te zien, CAD-bestanden te downloaden en direct online te bestellen.

Aanmelden Account aanvragen

Technische gegevens

Code GN 113.3-20-110
d1 -0.04/-0.08 20
d1 20
l1 110
l1 +0.6 110
d2 25
d3 28
l2 20.5
l2 ±1 20.5
l3+0.2 39
Location
bore H11
20
Axial holding force in
N≈
244
Load F in kN ≈
Load capacity in kN ≈
Double sided
shearing resistance
according DIN 50141
(breaking strength)
244
449

Stainless Steel AISI 303

Balls

Stainless Steel AISI 420C

Spring

Stainless Steel AISI 631

temperature resistant up to 250 °C

Stainless Steel-Ball lock pins GN 113.3 are used for quick fixing, connecting and locking of various parts and workpieces. A typical application is locating pins which have often to be removed and installed again.

By pressing the spring loaded push button both balls are unlocked and by releasing it the balls are locked again.

Ball lock pins GN 113.3 are renowned for their compactness. The eye ring is enclosed unmounted.

The load values given in the above table at shear stress are theoretically obtained and indicative only. They are non-binding recommended values and rule out any liability. They constitute no general warranty of quality and condition. The user must determine from case to case whether a product is suitable for the intended use.

 

Information

The load capacities specified in the table for the double sided shearing resistance (breaking strength) have been calculated or theoretically defined on the basis of DIN 50141.

At the same time, the endangered bolt cross-section S, according to a nearby sketch, was considered in two shear planes before breakage.

The details given on load rating are non-binding guide values without any liability. In general, they do not constitute a warranty of condition.

The user must determine whether the product is suitable for the intended purpose. Environmental factors can influence the specified values.

An appropriate safety factor must be taken into account in the design.

Load capacity F in kN ≈ double sided shearing resistance acc. DIN 50141 (breaking strength)