HCY-EIndicateurs de niveau électrique d'huile

Indicateurs de niveau électrique d'huile

avec capteur électrique de niveau MIN, technopolymère

Code
Description
f
d
A
B
C
H
L
e
h1
l
l1
111102
HCY.76-E-NC-M10
76
M10
16
29
32
46
108
41
37
40
17
111112
HCY.127-E-NC-M12
127
M12
16
29
32
46
159
93
37
40
29
111122
HCY.254-E-NC-M12
254
M12
16
29
32
46
286
219
37
40
29
Code
Description
f
d
A
B
C
H
L
e
h1
l
l1
111101
HCY.76-E-NO-M10
76
M10
16
29
32
46
108
41
37
40
17
111111
HCY.127-E-NO-M12
127
M12
16
29
32
46
159
93
37
40
29
111121
HCY.254-E-NO-M12
254
M12
16
29
32
46
286
219
37
40
29
# Maximum tightening torque

Material

Transparent polyamide based (PA-T) technopolymer. Highly resistant to shocks, solvents, oils with additives, aliphatic and aromatic hydrocarbons, petrol, naphtha, phosphoric esters.

Avoid contact with alcohol or detergents containing alcohol.

Screws

Nickel-plated brass with hexagon socket.

Packing rings

NBR synthetic rubber O-Ring.

Float

Polyamide based (PA) technopolymer in red colour, with a built-in magnetic element to activate the electric contact when the oil level drops to the minimum set at 40mm over the screw axis (dimension l).

Sensor bracket

Watertight, black colour, with a built-in relay (reed).

For a correct assembly see Warnings.

Connector

Right side output including protection against water sprays (protection class IP 65 according to EN 60529 table-).

Contrast screen

White lacquered aluminium. The housing, in the appropriate external rear slot, guarantees the best protection from direct contact with fluid.

It can be taken out before assembly to allow the insertion of level lines or words.

Standard executions

  • HCY-E-NO: electric contact normally open that closes when the minimum level is reached.
  • HCY-E-NC: electric contact normally closed that opens when the minimum level is reached.

Maximum continuous working temperature

80°C (with oil).

Technical data

In laboratory tests carried out with mineral oil type CB68 (according to ISO 3498) at 23°C for a limited period of time, the weld stood up to: 14 bar (HCY.76), 9 bar (HCY.127) and 8 bar (HCY.254).

For use with other fluids and under different pressure and temperature conditions, please contact ELESA Technical Department.

In any case we suggest to verify the suitability of the product under the actual working conditions.

 
Electrical featuresMIN level sensor
Tension feedAC/DC
Electric contacts

NO normally open

NC normally closed

Maximum applicable voltage

NC: 150 Vac, 150 Vdc

NO: 230 Vac, 230 Vdc

Maximum commutable opening capacity

NC: 1A

NO: 2A

Maximum commutable power

NC: 20 W / 20 V.A.

NO: 40 W / 40 V.A.

Cable glandPg 7 (for cables in sheath with Ø 6 or 7 mm)
Conductors cross-sectionMax. 1.5 mm2
Do not mount this indicator in proximity to magnetic fields.

Special executions on request

  • Column level indicators in different materials (polycarbonate), for use with special fluids and/or at high temperatures.
  • AISI 316 stainless steel or nickel-plated brass screws
  • Column level indicators with change-over electrical contact.

Two-pin connector assembly instructions

  1. Remove the connector from the indicator by unscrewing the set screw placed in the bottom, take the contact holder out and loosen the cable gland.
  2. Slip on the two-pole cable into the connector (standard connector) and connect the wires to the terminals nr. 1 and nr. 2 of the contact holder.
  3. Assemble by pressing the contact holder into the connector in the required position.
  4. Screw the connectors to the indicator and then tighten the cable glands.
 
Produits associés
Indicateurs au niveau des colonnes

HCX-E

Indicateurs au niveau des colonnes avec capteur électrique de niveau MIN, technopolymère
Indicateurs de niveau électrique d'huile

HCY-E-ST

Indicateurs de niveau électrique d'huile avec capteurs électriques de niveau MIN et de température MAX, technopolymère