113.7-6-60

GN 113.7 Goupilles de verrouillage à bille

Goupille en acier inoxydable AISI 303, avec poignée en T
  • Icons/__logo__INOX__.png
  • Icons/__logo__RoHS__.png

En stock Toutes les tailles et variantes de GN 113.7

🔒 Prix, stock en temps réel & téléchargements CAO

Connectez-vous pour voir vos prix et le stock, télécharger les fichiers CAO et commander directement en ligne.

Se connecter Demander un compte

Caractéristiques techniques

Code
GN 113.7-6-60
d1 -0.04/-0.08
6
l1 +0.6
60
d2
7
d3
40
d4
13.5
l2 ±1
7.1
l3
25
m
15.5
Location
bore H11
6
Load in kN ≈
Load capacity in kN ≈
Double sided
shearing resistance
according DIN 50141
(breaking strength)
21
24

Pin

Stainless steel AISI 303

T-Handle

Plastic (Polyamide PA)

  • Black
  • Temperature resistant up to 80 °C

Balls

Stainless steel AISI 420C

Pressure spring

Stainless steel German Material No. 14565

Ball lock pins GN 113.7 are used for quick fixing, connecting and locking of various parts and workpieces. A typical application is locating pins which have often to be removed and installed again.

By pressing the spring loaded push button both balls are unlocked and by releasing it, the balls are locked again.

The technical appendix contains the load capacities for the double-sided shearing resistance (breaking strength).

 

Information

The load capacities specified in the table for the double sided shearing resistance (breaking strength) have been calculated or theoretically defined on the basis of DIN 50141.

At the same time, the endangered bolt cross-section S, according to a nearby sketch, was considered in two shear planes before breakage.

The details given on load rating are non-binding guide values without any liability. In general, they do not constitute a warranty of condition.

The user must determine whether the product is suitable for the intended purpose. Environmental factors can influence the specified values.

An appropriate safety factor must be taken into account in the design.

Load capacity F in kN ≈ double sided shearing resistance acc. DIN 50141 (breaking strength)