HCK-E-SElectrical level indicators

Electrical level indicators

with MIN level electrical sensor, temperature sensor or probe

Catalogue
Description
f
d
A
B
C
H
L
e
l
l1
l2
113019
HCK.127-ZN-M12-NBR-PC-P-E-NC-80-NC
127
M12
20
33
33
59
164
56
55
61.5
46.5
113017
HCK.127-ZN-M12-NBR-PC-P-E-NO-80-NO
127
M12
20
33
33
59
164
56
55
61.5
46.5
114019
HCK.176-ZN-M12-NBR-PC-P-E-NC-80-NC
176
M12
20
33
33
59
213
105
55
61.5
46.5
114017
HCK.176-ZN-M12-NBR-PC-P-E-NO-80-NO
176
M12
20
33
33
59
213
105
55
61.5
46.5
116119
HCK.254-ZN-M12-NBR-PC-P-E-NC-80-NC
254
M12
20
33
33
59
291
183
55
61.5
46.5
116117
HCK.254-ZN-M12-NBR-PC-P-E-NO-80-NO
254
M12
20
33
33
59
291
183
55
61.5
46.5
117019
HCK.381-ZN-M12-NBR-PC-P-E-NC-80-NC
381
M12
20
33
33
59
418
310
55
61.5
46.5
117017
HCK.381-ZN-M12-NBR-PC-P-E-NO-80-NO
381
M12
20
33
33
59
418
310
55
61.5
46.5
117919
HCK.508-ZN-M12-NBR-PC-P-E-NC-80-NC
508
M12
20
33
33
59
545
437
55
61.5
46.5
117917
HCK.508-ZN-M12-NBR-PC-P-E-NO-80-NO
508
M12
20
33
33
59
545
437
55
61.5
46.5
113149
HCK.127-ZN-M12-FKM-PC-P-E-NC-80-NC
127
M12
20
33
33
59
164
56
55
61.5
46.5
113147
HCK.127-ZN-M12-FKM-PC-P-E-NO-80-NO
127
M12
20
33
33
59
164
56
55
61.5
46.5
114149
HCK.176-ZN-M12-FKM-PC-P-E-NC-80-NC
176
M12
20
33
33
59
213
105
55
61.5
46.5
114147
HCK.176-ZN-M12-FKM-PC-P-E-NO-80-NO
176
M12
20
33
33
59
213
105
55
61.5
46.5
116249
HCK.254-ZN-M12-FKM-PC-P-E-NC-80-NC
254
M12
20
33
33
59
291
183
55
61.5
46.5
116247
HCK.254-ZN-M12-FKM-PC-P-E-NO-80-NO
254
M12
20
33
33
59
291
183
55
61.5
46.5
117159
HCK.381-ZN-M12-FKM-PC-P-E-NC-80-NC
381
M12
20
33
33
59
418
310
55
61.5
46.5
117157
HCK.381-ZN-M12-FKM-PC-P-E-NO-80-NO
381
M12
20
33
33
59
418
310
55
61.5
46.5
118069
HCK.508-ZN-M12-FKM-PC-P-E-NC-80-NC
508
M12
20
33
33
59
545
437
55
61.5
46.5
118067
HCK.508-ZN-M12-FKM-PC-P-E-NO-80-NO
508
M12
20
33
33
59
545
437
55
61.5
46.5
113167
HCK.127-ZN-M12-FKM-PC-P-EHT-NC-80-NC
127
M12
20
33
33
59
164
56
55
61.5
46.5
113165
HCK.127-ZN-M12-FKM-PC-P-EHT-NO-80-NO
127
M12
20
33
33
59
164
56
55
61.5
46.5
114167
HCK.176-ZN-M12-FKM-PC-P-EHT-NC-80-NC
176
M12
20
33
33
59
213
105
55
61.5
46.5
114165
HCK.176-ZN-M12-FKM-PC-P-EHT-NO-80-NO
176
M12
20
33
33
59
213
105
55
61.5
46.5
116267
HCK.254-ZN-M12-FKM-PC-P-EHT-NC-80-NC
254
M12
20
33
33
59
291
183
55
61.5
46.5
116265
HCK.254-ZN-M12-FKM-PC-P-EHT-NO-80-NO
254
M12
20
33
33
59
291
183
55
61.5
46.5
117177
HCK.381-ZN-M12-FKM-PC-P-EHT-NC-80-NC
381
M12
20
33
33
59
418
310
55
61.5
46.5
117175
HCK.381-ZN-M12-FKM-PC-P-EHT-NO-80-NO
381
M12
20
33
33
59
418
310
55
61.5
46.5
118087
HCK.508-ZN-M12-FKM-PC-P-EHT-NC-80-NC
508
M12
20
33
33
59
545
437
55
61.5
46.5
118085
HCK.508-ZN-M12-FKM-PC-P-EHT-NO-80-NO
508
M12
20
33
33
59
545
437
55
61.5
46.5
113061
HCK.127-ZN-M12-NBR-GL-P-E-NC-80-NC
127
M12
20
33
33
59
164
56
55
61.5
46.5
113059
HCK.127-ZN-M12-NBR-GL-P-E-NO-80-NO
127
M12
20
33
33
59
164
56
55
61.5
46.5
114061
HCK.176-ZN-M12-NBR-GL-P-E-NC-80-NC
176
M12
20
33
33
59
213
105
55
61.5
46.5
114059
HCK.176-ZN-M12-NBR-GL-P-E-NO-80-NO
176
M12
20
33
33
59
213
105
55
61.5
46.5
116161
HCK.254-ZN-M12-NBR-GL-P-E-NC-80-NC
254
M12
20
33
33
59
291
183
55
61.5
46.5
116159
HCK.254-ZN-M12-NBR-GL-P-E-NO-80-NO
254
M12
20
33
33
59
291
183
55
61.5
46.5
117061
HCK.381-ZN-M12-NBR-GL-P-E-NC-80-NC
381
M12
20
33
33
59
418
310
55
61.5
46.5
117059
HCK.381-ZN-M12-NBR-GL-P-E-NO-80-NO
381
M12
20
33
33
59
418
310
55
61.5
46.5
117961
HCK.508-ZN-M12-NBR-GL-P-E-NC-80-NC
508
M12
20
33
33
59
545
437
55
61.5
46.5
117959
HCK.508-ZN-M12-NBR-GL-P-E-NO-80-NO
508
M12
20
33
33
59
545
437
55
61.5
46.5
113193
HCK.127-ZN-M12-FKM-GL-P-E-NC-80-NC
127
M12
20
33
33
59
164
56
55
61.5
46.5
113191
HCK.127-ZN-M12-FKM-GL-P-E-NO-80-NO
127
M12
20
33
33
59
164
56
55
61.5
46.5
114193
HCK.176-ZN-M12-FKM-GL-P-E-NC-80-NC
176
M12
20
33
33
59
213
105
55
61.5
46.5
114191
HCK.176-ZN-M12-FKM-GL-P-E-NO-80-NO
176
M12
20
33
33
59
213
105
55
61.5
46.5
116293
HCK.254-ZN-M12-FKM-GL-P-E-NC-80-NC
254
M12
20
33
33
59
291
183
55
61.5
46.5
116291
HCK.254-ZN-M12-FKM-GL-P-E-NO-80-NO
254
M12
20
33
33
59
291
183
55
61.5
46.5
117203
HCK.381-ZN-M12-FKM-GL-P-E-NC-80-NC
381
M12
20
33
33
59
418
310
55
61.5
46.5
117201
HCK.381-ZN-M12-FKM-GL-P-E-NO-80-NO
381
M12
20
33
33
59
418
310
55
61.5
46.5
118113
HCK.508-ZN-M12-FKM-GL-P-E-NC-80-NC
508
M12
20
33
33
59
545
437
55
61.5
46.5
118111
HCK.508-ZN-M12-FKM-GL-P-E-NO-80-NO
508
M12
20
33
33
59
545
437
55
61.5
46.5
113211
HCK.127-ZN-M12-FKM-GL-P-EHT-NC-80-NC
127
M12
20
33
33
59
164
56
55
61.5
46.5
113209
HCK.127-ZN-M12-FKM-GL-P-EHT-NO-80-NO
127
M12
20
33
33
59
164
56
55
61.5
46.5
114211
HCK.176-ZN-M12-FKM-GL-P-EHT-NC-80-NC
176
M12
20
33
33
59
213
105
55
61.5
46.5
114209
HCK.176-ZN-M12-FKM-GL-P-EHT-NO-80-NO
176
M12
20
33
33
59
213
105
55
61.5
46.5
116311
HCK.254-ZN-M12-FKM-GL-P-EHT-NC-80-NC
254
M12
20
33
33
59
291
183
55
61.5
46.5
116309
HCK.254-ZN-M12-FKM-GL-P-EHT-NO-80-NO
254
M12
20
33
33
59
291
183
55
61.5
46.5
117221
HCK.381-ZN-M12-FKM-GL-P-EHT-NC-80-NC
381
M12
20
33
33
59
418
310
55
61.5
46.5
117219
HCK.381-ZN-M12-FKM-GL-P-EHT-NO-80-NO
381
M12
20
33
33
59
418
310
55
61.5
46.5
118131
HCK.508-ZN-M12-FKM-GL-P-EHT-NC-80-NC
508
M12
20
33
33
59
545
437
55
61.5
46.5
118129
HCK.508-ZN-M12-FKM-GL-P-EHT-NO-80-NO
508
M12
20
33
33
59
545
437
55
61.5
46.5
113319
HCK.127-SST-M12-NBR-PC-P-E-NC-80-NC
127
M12
20
33
33
59
164
56
55
61.5
46.5
113317
HCK.127-SST-M12-NBR-PC-P-E-NO-80-NO
127
M12
20
33
33
59
164
56
55
61.5
46.5
114289
HCK.176-SST-M12-NBR-PC-P-E-NC-80-NC
176
M12
20
33
33
59
213
105
55
61.5
46.5
114287
HCK.176-SST-M12-NBR-PC-P-E-NO-80-NO
176
M12
20
33
33
59
213
105
55
61.5
46.5
116399
HCK.254-SST-M12-NBR-PC-P-E-NC-80-NC
254
M12
20
33
33
59
291
183
55
61.5
46.5
116397
HCK.254-SST-M12-NBR-PC-P-E-NO-80-NO
254
M12
20
33
33
59
291
183
55
61.5
46.5
117309
HCK.381-SST-M12-NBR-PC-P-E-NC-80-NC
381
M12
20
33
33
59
418
310
55
61.5
46.5
117307
HCK.381-SST-M12-NBR-PC-P-E-NO-80-NO
381
M12
20
33
33
59
418
310
55
61.5
46.5
118219
HCK.508-SST-M12-NBR-PC-P-E-NC-80-NC
508
M12
20
33
33
59
545
437
55
61.5
46.5
118217
HCK.508-SST-M12-NBR-PC-P-E-NO-80-NO
508
M12
20
33
33
59
545
437
55
61.5
46.5
113451
HCK.127-SST-M12-FKM-PC-P-E-NC-80-NC
127
M12
20
33
33
59
164
56
55
61.5
46.5
113449
HCK.127-SST-M12-FKM-PC-P-E-NO-80-NO
127
M12
20
33
33
59
164
56
55
61.5
46.5
114429
HCK.176-SST-M12-FKM-PC-P-E-NC-80-NC
176
M12
20
33
33
59
213
105
55
61.5
46.5
114427
HCK.176-SST-M12-FKM-PC-P-E-NO-80-NO
176
M12
20
33
33
59
213
105
55
61.5
46.5
116539
HCK.254-SST-M12-FKM-PC-P-E-NC-80-NC
254
M12
20
33
33
59
291
183
55
61.5
46.5
116537
HCK.254-SST-M12-FKM-PC-P-E-NO-80-NO
254
M12
20
33
33
59
291
183
55
61.5
46.5
117449
HCK.381-SST-M12-FKM-PC-P-E-NC-80-NC
381
M12
20
33
33
59
418
310
55
61.5
46.5
117447
HCK.381-SST-M12-FKM-PC-P-E-NO-80-NO
381
M12
20
33
33
59
418
310
55
61.5
46.5
118359
HCK.508-SST-M12-FKM-PC-P-E-NC-80-NC
508
M12
20
33
33
59
545
437
55
61.5
46.5
118357
HCK.508-SST-M12-FKM-PC-P-E-NO-80-NO
508
M12
20
33
33
59
545
437
55
61.5
46.5
113469
HCK.127-SST-M12-FKM-PC-P-EHT-NC-80-NC
127
M12
20
33
33
59
164
56
55
61.5
46.5
113467
HCK.127-SST-M12-FKM-PC-P-EHT-NO-80-NO
127
M12
20
33
33
59
164
56
55
61.5
46.5
114447
HCK.176-SST-M12-FKM-PC-P-EHT-NC-80-NC
176
M12
20
33
33
59
213
105
55
61.5
46.5
114445
HCK.176-SST-M12-FKM-PC-P-EHT-NO-80-NO
176
M12
20
33
33
59
213
105
55
61.5
46.5
116557
HCK.254-SST-M12-FKM-PC-P-EHT-NC-80-NC
254
M12
20
33
33
59
291
183
55
61.5
46.5
116555
HCK.254-SST-M12-FKM-PC-P-EHT-NO-80-NO
254
M12
20
33
33
59
291
183
55
61.5
46.5
117467
HCK.381-SST-M12-FKM-PC-P-EHT-NC-80-NC
381
M12
20
33
33
59
418
310
55
61.5
46.5
117465
HCK.381-SST-M12-FKM-PC-P-EHT-NO-80-NO
381
M12
20
33
33
59
418
310
55
61.5
46.5
118377
HCK.508-SST-M12-FKM-PC-P-EHT-NC-80-NC
508
M12
20
33
33
59
545
437
55
61.5
46.5
118375
HCK.508-SST-M12-FKM-PC-P-EHT-NO-80-NO
508
M12
20
33
33
59
545
437
55
61.5
46.5
113363
HCK.127-SST-M12-NBR-GL-P-E-NC-80-NC
127
M12
20
33
33
59
164
56
55
61.5
46.5
113361
HCK.127-SST-M12-NBR-GL-P-E-NO-80-NO
127
M12
20
33
33
59
164
56
55
61.5
46.5
114333
HCK.176-SST-M12-NBR-GL-P-E-NC-80-NC
176
M12
20
33
33
59
213
105
55
61.5
46.5
114331
HCK.176-SST-M12-NBR-GL-P-E-NO-80-NO
176
M12
20
33
33
59
213
105
55
61.5
46.5
116443
HCK.254-SST-M12-NBR-GL-P-E-NC-80-NC
254
M12
20
33
33
59
291
183
55
61.5
46.5
116441
HCK.254-SST-M12-NBR-GL-P-E-NO-80-NO
254
M12
20
33
33
59
291
183
55
61.5
46.5
117353
HCK.381-SST-M12-NBR-GL-P-E-NC-80-NC
381
M12
20
33
33
59
418
310
55
61.5
46.5
117351
HCK.381-SST-M12-NBR-GL-P-E-NO-80-NO
381
M12
20
33
33
59
418
310
55
61.5
46.5
118263
HCK.508-SST-M12-NBR-GL-P-E-NC-80-NC
508
M12
20
33
33
59
545
437
55
61.5
46.5
118261
HCK.508-SST-M12-NBR-GL-P-E-NO-80-NO
508
M12
20
33
33
59
545
437
55
61.5
46.5
113493
HCK.127-SST-M12-FKM-GL-P-E-NC-80-NC
127
M12
20
33
33
59
164
56
55
61.5
46.5
113491
HCK.127-SST-M12-FKM-GL-P-E-NO-80-NO
127
M12
20
33
33
59
164
56
55
61.5
46.5
114471
HCK.176-SST-M12-FKM-GL-P-E-NC-80-NC
176
M12
20
33
33
59
213
105
55
61.5
46.5
114469
HCK.176-SST-M12-FKM-GL-P-E-NO-80-NO
176
M12
20
33
33
59
213
105
55
61.5
46.5
116581
HCK.254-SST-M12-FKM-GL-P-E-NC-80-NC
254
M12
20
33
33
59
291
183
55
61.5
46.5
116579
HCK.254-SST-M12-FKM-GL-P-E-NO-80-NO
254
M12
20
33
33
59
291
183
55
61.5
46.5
117491
HCK.381-SST-M12-FKM-GL-P-E-NC-80-NC
381
M12
20
33
33
59
418
310
55
61.5
46.5
117489
HCK.381-SST-M12-FKM-GL-P-E-NO-80-NO
381
M12
20
33
33
59
418
310
55
61.5
46.5
118401
HCK.508-SST-M12-FKM-GL-P-E-NC-80-NC
508
M12
20
33
33
59
545
437
55
61.5
46.5
118399
HCK.508-SST-M12-FKM-GL-P-E-NO-80-NO
508
M12
20
33
33
59
545
437
55
61.5
46.5
113511
HCK.127-SST-M12-FKM-GL-P-EHT-NC-80-NC
127
M12
20
33
33
59
164
56
55
61.5
46.5
113509
HCK.127-SST-M12-FKM-GL-P-EHT-NO-80-NO
127
M12
20
33
33
59
164
56
55
61.5
46.5
114489
HCK.176-SST-M12-FKM-GL-P-EHT-NC-80-NC
176
M12
20
33
33
59
213
105
55
61.5
46.5
114487
HCK.176-SST-M12-FKM-GL-P-EHT-NO-80-NO
176
M12
20
33
33
59
213
105
55
61.5
46.5
116599
HCK.254-SST-M12-FKM-GL-P-EHT-NC-80-NC
254
M12
20
33
33
59
291
183
55
61.5
46.5
116597
HCK.254-SST-M12-FKM-GL-P-EHT-NO-80-NO
254
M12
20
33
33
59
291
183
55
61.5
46.5
117509
HCK.381-SST-M12-FKM-GL-P-EHT-NC-80-NC
381
M12
20
33
33
59
418
310
55
61.5
46.5
117507
HCK.381-SST-M12-FKM-GL-P-EHT-NO-80-NO
381
M12
20
33
33
59
418
310
55
61.5
46.5
118419
HCK.508-SST-M12-FKM-GL-P-EHT-NC-80-NC
508
M12
20
33
33
59
545
437
55
61.5
46.5
118417
HCK.508-SST-M12-FKM-GL-P-EHT-NO-80-NO
508
M12
20
33
33
59
545
437
55
61.5
46.5
113619
HCK.127-A4-M12-NBR-PC-P-E-NC-80-NC
127
M12
20
33
33
59
164
56
55
61.5
46.5
113617
HCK.127-A4-M12-NBR-PC-P-E-NO-80-NO
127
M12
20
33
33
59
164
56
55
61.5
46.5
114589
HCK.176-A4-M12-NBR-PC-P-E-NC-80-NC
176
M12
20
33
33
59
213
105
55
61.5
46.5
114587
HCK.176-A4-M12-NBR-PC-P-E-NO-80-NO
176
M12
20
33
33
59
213
105
55
61.5
46.5
116699
HCK.254-A4-M12-NBR-PC-P-E-NC-80-NC
254
M12
20
33
33
59
291
183
55
61.5
46.5
116697
HCK.254-A4-M12-NBR-PC-P-E-NO-80-NO
254
M12
20
33
33
59
291
183
55
61.5
46.5
117609
HCK.381-A4-M12-NBR-PC-P-E-NC-80-NC
381
M12
20
33
33
59
418
310
55
61.5
46.5
117607
HCK.381-A4-M12-NBR-PC-P-E-NO-80-NO
381
M12
20
33
33
59
418
310
55
61.5
46.5
118519
HCK.508-A4-M12-NBR-PC-P-E-NC-80-NC
508
M12
20
33
33
59
545
437
55
61.5
46.5
118517
HCK.508-A4-M12-NBR-PC-P-E-NO-80-NO
508
M12
20
33
33
59
545
437
55
61.5
46.5
113751
HCK.127-A4-M12-FKM-PC-P-E-NC-80-NC
127
M12
20
33
33
59
164
56
55
61.5
46.5
113749
HCK.127-A4-M12-FKM-PC-P-E-NO-80-NO
127
M12
20
33
33
59
164
56
55
61.5
46.5
114729
HCK.176-A4-M12-FKM-PC-P-E-NC-80-NC
176
M12
20
33
33
59
213
105
55
61.5
46.5
114727
HCK.176-A4-M12-FKM-PC-P-E-NO-80-NO
176
M12
20
33
33
59
213
105
55
61.5
46.5
116839
HCK.254-A4-M12-FKM-PC-P-E-NC-80-NC
254
M12
20
33
33
59
291
183
55
61.5
46.5
116837
HCK.254-A4-M12-FKM-PC-P-E-NO-80-NO
254
M12
20
33
33
59
291
183
55
61.5
46.5
117749
HCK.381-A4-M12-FKM-PC-P-E-NC-80-NC
381
M12
20
33
33
59
418
310
55
61.5
46.5
117747
HCK.381-A4-M12-FKM-PC-P-E-NO-80-NO
381
M12
20
33
33
59
418
310
55
61.5
46.5
118659
HCK.508-A4-M12-FKM-PC-P-E-NC-80-NC
508
M12
20
33
33
59
545
437
55
61.5
46.5
118657
HCK.508-A4-M12-FKM-PC-P-E-NO-80-NO
508
M12
20
33
33
59
545
437
55
61.5
46.5
113769
HCK.127-A4-M12-FKM-PC-P-EHT-NC-80-NC
127
M12
20
33
33
59
164
56
55
61.5
46.5
113767
HCK.127-A4-M12-FKM-PC-P-EHT-NO-80-NO
127
M12
20
33
33
59
164
56
55
61.5
46.5
114747
HCK.176-A4-M12-FKM-PC-P-EHT-NC-80-NC
176
M12
20
33
33
59
213
105
55
61.5
46.5
114745
HCK.176-A4-M12-FKM-PC-P-EHT-NO-80-NO
176
M12
20
33
33
59
213
105
55
61.5
46.5
116857
HCK.254-A4-M12-FKM-PC-P-EHT-NC-80-NC
254
M12
20
33
33
59
291
183
55
61.5
46.5
116855
HCK.254-A4-M12-FKM-PC-P-EHT-NO-80-NO
254
M12
20
33
33
59
291
183
55
61.5
46.5
117767
HCK.381-A4-M12-FKM-PC-P-EHT-NC-80-NC
381
M12
20
33
33
59
418
310
55
61.5
46.5
117765
HCK.381-A4-M12-FKM-PC-P-EHT-NO-80-NO
381
M12
20
33
33
59
418
310
55
61.5
46.5
118677
HCK.508-A4-M12-FKM-PC-P-EHT-NC-80-NC
508
M12
20
33
33
59
545
437
55
61.5
46.5
118675
HCK.508-A4-M12-FKM-PC-P-EHT-NO-80-NO
508
M12
20
33
33
59
545
437
55
61.5
46.5
# Maximum tightening torque.
  • Icons/__logo__ELE_OD__.png

Assembly ends

Glass-fibre reinforced polyamide based (PA) technopolymer, black colour.

Support

Aluminium in natural colour.

Graduated contrast screen

White lacquered aluminium. It can be taken out before assembly to allow the insertion of level lines or words.

Float

Technopolymer, black colour, with a built-in magnetic element to activate the electric contact when the float reaches the contact threshold located at about 55 mm above the axis of the lower screw (data referred to mineral oil type CB68, according to ISO 3498, temperature 23°C).

Spacer sleeves

In polyamide based (PA) technopolymer. Essential in cases where the reservoir is made out of ferromagnetic material in order to prevent the interaction between the magnet and the metal mass of the reservoir.

Bracket with male connector

Perfectly watertight, incorporating the relay (reed) with two output conductors (NO and NC version) and/or with MAX temperature sensor (80°C) and/or temperature probe.

  • DIN 43650 C connector in glass-fibre reinforced polyamide based (PA) technopolymer, black colour.
  • 4-pole M12x1 connector, with threading in glass-fibre reinforced polyamide based (PA) technopolymer certified self-extinguishing UL-94-V0, black colour, matte finish.

For a correct assembly see Warnings.

Female connector (DIN 43650 C)

With built-in cable gland and contact holder. Front or axial output (high or low) ensuring protection against water sprays (protection class IP 65 according to table EN 60529).

Standard executions

See configuration table.

 
 

Features and performances

The HCK-E-S level indicator with lateral connector output allows the level of intervention of the sensor to be minimised.

In case of use of an extension with angled connector, the direction of the cable output is shown in Fig.1.

Technical data

In laboratory tests carried out for a relatively limited time with the following liquids at a temperature of 23° C: mineral oil type CB68 (according to ISO 3498) for HCK, mineral oil type CB68 (according to ISO 3498) water or water/glycol-based solutions ( 50%) for HCK-GL, the resistance values were much higher than 35 bar.

For use with fluids other than mineral oils and under particular different pressure and temperature conditions, please contact ELESA Technical Department.

In any case we suggest to verify the suitability of the product under the actual working conditions.

Functioning of the MIN level electrical sensor

  • NO: the electrical contact closes on reaching the minimum level.
  • NC: the electrical contact is opened when it reaches the minimum level.
 
 
HCK-E-ST - HCK-E-ST-KN
Electrical featuresMIN level sensor
Power supplyAC/DC
Electric contacts

NO normally open

NC normally closed

Maximum applicable voltage

NO: 140 Vac, 200 Vdc

NC: 140Vac, 150 Vdc

Maximum switching current1 A
Maximum current

NO: 1.2A

NC: 2A

Maximum commutable power

NO: 10 Va

NC: 20 Va

Cable gland (only HCK-E-ST)Pg 7 (for cables in sheath with Ø 6 or 7 mm)
Conductors cross-section (only HCK-E-ST)Max. 1.5 mm2
Connector (only HCK-E-ST-KN)M12x1
Do not mount this indicator in proximity to magnetic fields.
 
 
HCK-E-STL - HCK-E-STL-KN
Electrical featuresMIN level sensor
Power supplyAC/DC
Electric contacts

NO normally open

NC normally closed

Maximum applicable voltage

NO: 140 Vac, 200 Vdc

NC: 140Vac, 150 Vdc

Maximum switching current1 A
Maximum current

NO: 1.2A

NC: 2A

Maximum commutable power

NO: 10 Va

NC: 20 Va

Cable gland (only HCK-E-STL)Pg 7 (for cables in sheath with Ø 6 or 7 mm)
Conductors cross-section (only HCK-E-STL)Max. 1.5 mm2
Connector (only HCK-E-STL-KN)M12x1
Do not mount this indicator in proximity to magnetic fields.

Functioning of the MAX temperature sensor

  • NO: the electrical contact closes when the pre-set temperature is reached at 80°C.
  • NC: the electrical contact opens when the pre-set temperature at 80°C is reached.
 
 
HCK-E-ST - HCK-E-ST-KN
Electrical featuresMAX temperature sensor
Power supplyAC/DC
Electric contacts

NO normally open

NC normally closed

Voltage /

Maximum current

250 Vac - 2 A(resistive loads)
115 Vac- 3A
24 Vdc - 3 A
12 Vdc - 4 A
Minimum current500 mA
Cable gland (only HCK-E-ST)Pg 7 (for cables in sheath with Ø 6 or 7 mm)
Conductors cross-section (only HCK-E-ST)Max. 1.5 mm2
Connector (only HCK-E-ST-KN)M12x1
Do not mount this indicator in proximity to magnetic fields.

Functioning of the temperature electrical probe (STL)

The working principle of the temperature probe is to measure the variation of resistance of a platinum element: 100 ohm = 0°C, 138.4 ohm = 100°C.

The function between temperature (T) and resistance (R) is approximately linear over a small temperature range: for example, if you assume that it is linear over the 0° to 100°C range, the error at 50°C is 0.4°C.

For precision measurement, it is necessary to linearise the resistance to give an accurate temperature. The most recent definition of the function between resistance and temperature is International Temperature Standard 90 (ITS-90). The function between resistance and temperature, obtained in laboratory tests, measuring directly the resistance value on the contacts is shown in the graph. We suggest, anyway, to set the system in order to compensate both heat dissipation and cable resistance.

The temperature variation of 1°C causes a 0.384 ohm variation in the probe resistance. Therefore, even a small error in the resistance measurement (for example, if the resistance of the cables connecting to the probe were not considered) translates into a significant error in the temperature measurement.

Because of the low signal levels, it is important to keep any cables away from electric cables, motors, switchgear and other devices that may emit magnetic or electrical noise. Using screened cable, with the screen grounded at one end, may help to reduce interference.

Furthermore, if long connection cables are used, make sure that the signal measurement and reception device is designed to compensate for the resistance of the cables themselves.

 
 
 
HCK-E-STL - HCK-E-STL-KN
Electrical featuresTemperature probe
Power supplyAC/DC
Maximum current1mA
Cable gland (only HCK-E-STL)Pg 7 (for cables in sheath with Ø 6 or 7 mm)
Conductors cross-section (only HCK-E-STL)Max. 1.5 mm2
Connector (only HCK-E-STL-KN)M12x1
Do not mount this indicator in proximity to magnetic fields.

Special executions on request

  • Column level window in transparent methylmatacrylate (PMMA) for max 70°C use.
  • Polyamide based technopolymer float (from HCK.127) red colour.
  • NBR float (from HCK.176) black colour with AISI 316 stainless steel spiral for special executions, viscous liquids, high temperatures.
  • Indicators with level visibility (quota) up to 1429 mm and fixing holes with centre distance (quota f) up to 1500 mm.
  • Packing rings in special material depending on the customer's needs.
  • Special screw with nickel-plated brass tap to be fitted to the lower assembly end for any maintenance operation requiring the indicator exclusion.

Accessories on request

FC.M12x1: extensions with 4 pole M12 female axial connector.

Female connector assembly instructions

  • Remove the connector from the indicator by unscrewing the set screw placed on the connector, take the contact holders out and loosen the cable gland.
  • a) HCK-E-ST: insert the cable into the connector (standard connector) and connect the wires to terminals 1 and 2 for the operation of the MIN level sensor, to terminals 3 and ground (4) for the operation of the MAX temperature sensor.
  • b) HCK-E-STL: insert the cable into the connector (standard connector) and connect the wires to terminals 1 and 2 for the operation of the MIN level sensor, to terminals 3 and ground (4) for the operation of the temperature probe.
  • Assemble by pressing the contact holder into the connector in the required position.
  • Screw the connectors to the indicator and then tighten the cable glands.
 
 
Related products
Electrical level indicators

HCK-E

Electrical level indicators with MIN level electrical sensor
Electrical level indicators

HCK-S

Electrical level indicators with temperature sensor or probe
Electrical level indicators

HCV-E

Electrical level indicators with MIN level electrical sensor, transparent technopolymer
Electrical level indicators

HCV-E-S

Electrical level indicators with MIN level electrical sensor, temperature sensor and probe, transparent technopolymer
Electrical level indicators

HCV-S

Electrical level indicators with temperature sensor and probe, transparent technopolymer
Oil electrical level indicators

HCY-E

Oil electrical level indicators with MIN level electrical sensor, technopolymer
Oil electrical level indicators

HCY-E-ST

Oil electrical level indicators with MIN level and MAX temperature electrical sensors, technopolymer