with Horizontal Mounting Base
Catalogue
|
Size
|
FH in N
|
FS in N
|
a ≈
|
b1
|
b2
|
d1
|
d2
|
d3
|
Inside ø
connection tube |
h1
|
h2
|
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
GN 860-75-AP-M
|
75
|
700
|
380
|
20
|
40
|
5.2
|
M 5
|
4.5
|
M 5
|
4
|
54
|
22
|
GN 860-130-AP-M
|
130
|
1600
|
800
|
28
|
47.5
|
6.2
|
M 6
|
5.6
|
G 1/8
|
4
|
66
|
30
|
GN 860-230-AP-M
|
230
|
2200
|
1200
|
40
|
52
|
8.2
|
M 8
|
6.7
|
G 1/8
|
4
|
78
|
36
|
GN 860-330-AP-M
|
330
|
2500
|
1750
|
45
|
74
|
10.5
|
M 10
|
8.6
|
G 1/4
|
6
|
96
|
46
|
GN 860-430-AP-M
|
430
|
4000
|
3200
|
48
|
73
|
12.5
|
M 12
|
8.5
|
G 1/4
|
8
|
115
|
55
|
Sheet metal parts
Case-hardened steel C10
Zinc plated, blue passivated
Bearing pins hardened
Bearing rivets
Case-hardened
Air cylinder bearing pins
Case-hardened
Double-action air cylinder
Max. pressure 6 bar
All moving parts
Lubricated with special grease
Clamping screw GN 708.1, type A
The clamping principle of toggle clamps GN 860 is identical in construction and dimensions to the manually operated vertical toggle clamps GN 810 .
To ensure an extended life of the mechanical parts as well as the air cylinders the operating pressure should not exceed 6 bar and a compressed air maintenance unit should be installed upstream.
Toggle clamps GN 860 have a permanent magnet integrated into the piston. In conjunction with sensors GN 3380, it is possible to detect the end position, such as for implementing machine controls.