with sensor for position monitoring
Catalogue
|
d1 Pin -0.02/-0.05
Bore H7 |
l1
|
Cable length l5 in meter
|
d2
|
d3
|
d4
|
k
|
l2
|
l3
|
l4
|
A/F
|
Spring load
in N≈ initial |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
GN 817.6-4-6-EB-S-0,5
|
4
|
6
|
0.5
|
M 8 x 1
|
16
|
2
|
14
|
41.5
|
16
|
11.5
|
10
|
4
|
GN 817.6-5-8-EB-S-0,5
|
5
|
8
|
0.5
|
M 10 x 1
|
19
|
2
|
16
|
46.5
|
18
|
12.5
|
12
|
5
|
GN 817.6-6-9-EB-S-0,5
|
6
|
9
|
0.5
|
M 12 x 1,5
|
23
|
2
|
20
|
54.5
|
22
|
12.5
|
14
|
6
|
GN 817.6-8-12-EB-S-0,5
|
8
|
12
|
0.5
|
M 16 x 1,5
|
28
|
2
|
24
|
64.5
|
26
|
14.5
|
17
|
8.5
|
GN 817.6-10-12-EB-S-0,5
|
10
|
12
|
0.5
|
M 16 x 1,5
|
28
|
2
|
24
|
64.5
|
26
|
14.5
|
17
|
9.5
|
GN 817.6-12-15-EB-S-0,5
|
12
|
15
|
0.5
|
M 20 x 1,5
|
33
|
2
|
28.5
|
78
|
33
|
16.5
|
22
|
11.5
|
GN 817.6-16-20-EB-S-0,5
|
16
|
20
|
0.5
|
M 24 x 2
|
33
|
2
|
28.5
|
85
|
38
|
18.5
|
27
|
13
|
GN 817.6-4-6-EC-S-0,5
|
4
|
6
|
0.5
|
M 8 x 1
|
16
|
2
|
14
|
41.5
|
16
|
11.5
|
10
|
4
|
GN 817.6-5-8-EC-S-0,5
|
5
|
8
|
0.5
|
M 10 x 1
|
19
|
2
|
16
|
46.5
|
18
|
12.5
|
12
|
5
|
GN 817.6-6-9-EC-S-0,5
|
6
|
9
|
0.5
|
M 12 x 1,5
|
23
|
2
|
20
|
54.5
|
22
|
12.5
|
14
|
6
|
GN 817.6-8-12-EC-S-0,5
|
8
|
12
|
0.5
|
M 16 x 1,5
|
28
|
2
|
24
|
64.5
|
26
|
14.5
|
17
|
8.5
|
GN 817.6-10-12-EC-S-0,5
|
10
|
12
|
0.5
|
M 16 x 1,5
|
28
|
2
|
24
|
64.5
|
26
|
14.5
|
17
|
9.5
|
GN 817.6-12-15-EC-S-0,5
|
12
|
15
|
0.5
|
M 20 x 1,5
|
33
|
2
|
28.5
|
78
|
33
|
16.5
|
22
|
11.5
|
GN 817.6-16-20-EC-S-0,5
|
16
|
20
|
0.5
|
M 24 x 2
|
33
|
2
|
28.5
|
85
|
38
|
18.5
|
27
|
13
|
Stainless Steel
Knob, Plastic (Polyamide PA)
Magnet
Hard ferrite
Sensor / Sensor clip
Plastic (Polyamide PA), black, matte
Cable (Outer sheath)
Polyurethan PUR, black
Hex nut ISO 8675
Stainless Steel A2
Stainless Steel-Indexing plungers GN 817.6 with sensor for position monitoring allow for electronic monitoring of the plunger pin state. For this purpose, a magnet is integrated into the plunger pin that switches the sensor upon engaging after approx. 2/3 of the locking distance l1.
The sensor electronics then outputs a high signal, e.g. to a machine control, and additionally indicates this switch state with an LED on the sensor.
To prevent faults, no external magnetic fields should be acting on the indexing plunger. The Stainless Steel-Indexing plungers GN 817.6 are delivered with enclosed sensor, sensor clip, Allen® wrench and a hexagon nut.
The position of the sensor cable can be chosen freely during installation of the sensor clip.
Installation steps:
1. Insert the sensor into the sensor clip from the side.
2. Tighten the hexagon socket screw of the sensor.
3. Clip the sensor clip into the ring groove of the indexing plunger in any orientation and then adjust the direction by turning, if necessary.